The SPP-4009 switching transformer was designed for Lnk363P Power Integrations™ IC chip applications, and is also a high quality solution for many other products, including 3.0W cell phone chargers.
The following specifications will help you determine whether this switch mode power supply transformer is right for your project:
- Complies with IEC950, EN60950, UL1950/CSA950, supplementary insulation (300V).
- Designed for EN55022 and CISPR-22B for EMC noise performance.
- Meets CEC 2008 requirement of greater than 58.9% efficiency.
- 3.0W maximum (cell phone charger application), 1 DC output:
- +5V @ 600mADC.
- Dielectric strength: 3000Vrms primary to secondary, 1 second.
- 85-265Vac power supply.
- PC through-hole mounting style.
- Complies with EU RoHS directives.
The data sheet attached above will provide additional information on the SPP-4009 switching transformer.
In need of modifications, or an SMPS transformer built to your exact specifications? Our expert team can help. We build custom transformers, inductors and coils, tailored to your project needs. Request a free quote.